I-ACB kanye ne-MCCB
Isifinyezo
I-GPU1/2/3 Series i-smart universal air circuit breaker iklanyelwe imikhiqizo ethuthukisiwe yithi, i-voltage elinganiselwe ye-AC 50/60Hz, 480V(690V), elinganiselwe ngo-200A~6300A yamanje, ikakhulukazi esetshenziselwa ukusatshalaliswa kwamandla nokuvikela amasekhethi okusabalalisa amandla. inethiwekhi, ivimbela ukunikezwa kwamandla kanye nokulimala kwempahla kagesi ngenxa yephutha lokugcwala ngokweqile, i-short-circuit, iphutha lomhlaba, njll. Inokuvikela okukhethayo okunembayo okuphezulu futhi ithuthukisa ukuthembeka kokunikezwa kwamandla.I-Breaker futhi inomsebenzi wokuzihlukanisa, ihambisana nezinga le-GB 14048.2, IEC 60947-2
Izici
1. Isakhiwo esihlangene
2. Alikho ibanga le-flashover Ukuphepha okuphezulu
3. Umthamo ophezulu we-Off
4. Uhlobo oluhlakaniphile lokuvikela uhambo lwamanje, olunokuxhumana kokuxhumana, lungalawulwa iqoqo lekhompyutha, imisebenzi etholakala kude.
5. Umsebenzi wokubonisa we-ammeter, i-voltmeter
6. Okungenayo okuphezulu naphansi ngeke kuthinte ukusebenza komkhiqizo
Imodeli
GPU3 | I-Universal air circuit breaker |
1600 | I-Shield frame yamanje |
4 | 3 3-isigaba asimaki 4 4-Isigaba |
Isilawuli esihlakaniphile sohlobo lwe-3M | Isilawuli esihlakaniphile Uhlobo lwe-2M: Isibonisi seshubhu yedijithali, ukulungisa izinkinobho, isigaba esi-3 esinomsebenzi wokuvikela amaphutha omhlaba Uhlobo lwe-3M: Isibonisi se-LCD, ukulungisa izinkinobho, isigaba esi-3 esinomsebenzi wokuvikela amaphutha omhlaba Uhlobo lwe-3H: Isibonisi se-LCD, ukulungisa izinkinobho kanye nokuxhumana, isigaba esingu-3 nge umsebenzi wokuvikela amaphutha emhlabeni. |
Indlela yokukhweza | Uhlobo lokudweba Uhlobo olungaguquki |
Xhuma indlela | Izintambo ezivundlile izintambo eziqondile Izintambo ezingemuva kwepuleti |
Ukukhetha izesekeli | I-Under-voltage tripper I-interlokhi yomshini: amasethi ama-2 noma amasethi ama-3 ama-breaker ku-lever eqondile ehlanganisiwe 2 amasethi ama-breaker avundlile noma aqondile ahlanganiswe intambo yensimbi “Vula” indawo yokukhiya (ukukhiya ukhiye) I-Draw-out 3 isikhundla sokushintsha Isiguquli sesigaba se-N esixhumayo sangaphandle |
Ngo=630 | Ikalwe okwamanje(A) |
Qaphela:
1. Isilawuli esihlakaniphile siwuhlobo lwe-M;Iswishi yokusiza: Oxhumana nabo bamaqembu ama-4, Indlela yokuxhuma ivundlile.
2. Isilawuli esihlakaniphile, idivayisi yokukhishwa kwe-shunt, i-electromagnetic evaliwe, indlela yokushayela imoto kanye nesinqamuleli esingaphansi kwe-voltage kuzocaciswa inani le-voltage lapho u-oda.
Ithebula Lokukhetha Lobuchwepheshe
Uhlobo | I-voltage yokusebenza elinganiselwe i-Ue(V) | I-insulating elinganiselwe I-voltage Ui(V) | I-impulse elinganiselwe ukumelana ne-voltage Uimp (V) | Uhlaka lwesihlangu I-Inm yamanje (A) | Ikalwe okwamanje I-Inm (A) | Inombolo yesigaba |
I-GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
I-GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
I-GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
I-GPU1-6300 | 6300 | 4000, 5000, 6300 |
Amandla okuphuka kwesiyingi esifushane | Ilinganiselwe isikhathi esifushane imelana ne-Icw yamanje (kA)/1s | Ukusebenza komsebenzi | |||||
Isilinganiso esiphezulu somthamo we-Icu (kA) sokuphulwa kwesekethe emfushane | Ilinganiselwe ngokusebenza komthamo we-Ics (kA) | Impilo yemishini (izikhathi) | Impilo kagesi (izikhathi) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
I-GPM11 Ikesi Elibunjiwe Le-Circuit Breaker
GPM11Z Smart Molded Case Circuit Breaker
Isifinyezo se-GPM11/GPM11Z
I-GPM11 uchungechunge lwe-circuit breaker ilungele i-AC 50/ 60Hz elinganiselwe i-voltage yokusebenza engu-400V/630V, ikalwe njengamanje yafika ku-800A yenethiwekhi yokusatshalaliswa kwamandla ukuze kusatshalaliswe amandla namasekhethi okuvikela, ukuphakelwa kukagesi nezinto zokusebenza zikagesi ngokumelene nokugcwala, ugesi ongaphansi nogesi. izingozi zesekethe emfishane, ithuthukisa ukwethembeka kokuphakelwa kwamandla ngaphansi kwezimo ezivamile zokusetshenziswa okungaqali ukwenzeka njengokushintshwa kolayini kanye nenjini.Futhi ngomsebenzi wokuzihlukanisa futhi.Ihlangabezana nezinga le-GB/T 14048.2 ne-IEC 60947-2.
Imodeli
I-GPM11GPM11Z | Ikesi Elibunjiwe I-Circuit BreakerSmart Molded Case Circuit Breaker |
100 | I-Shield frame yamanje |
H | Umthamo wokuphulwa kwesekethe emfishane:N: Uhlobo olujwayelekile S: Uhlobo olujwayelekileH: Uhlobo oluphuka kakhulu |
P | Indlela yokusebenza: Ukusebenza kwezimoto: Ukusebenza kwesibambo se-Protate: Ukusebenza kwe-ZDirect (ayikho ikhodi) |
2 | Ukukhethwa kwesici sokuvikela:ukuvikelwa kokusabalalisa: akukho khodiUkuvikelwa kwemoto: 2 |
4 | Inombolo yesigaba2: izigaba ezimbili3: izigaba ezintathu4 : izigaba ezine |
208 | Indlela yohambo kanye nekhodi yezesekeli yangaphakathi |
Ku=100 | Ikalwe okwamanje(A) |
B | Isigaba esingu-4 sokunqamula isigaba esingu-N sinezinhlobo ezi-4 ezihlukene ezimakwe ngokuthi A, B, C, DA: Isigaba sika-N ngeke sifake i-tripper yamanje, futhi N ixhunywe njalo, ayisebenzi nezinye izigaba ezi-3. B: Isigaba esingu-N asifaki i-tripper yamanje, kanye no-N isigaba asisetshenziswanga nezinye izigaba ezi-3.C: Isigaba sika-N sifake i-tripper yamanje, futhi isigaba sika-N sisebenza nezinye izigaba ezi-3.D: Isigaba sika-N sifakwe i-tripper yamanje, futhi isigaba sika-N sixhumeke njalo, Asisebenzi nezinye izigaba ezi-3. |
Q | Indlela yokufaka izintambo:Phambili kwezintambo zepuleti: I-QIngemuva lezintambo zepuleti: HIzintambo zohlobo lwe-plug-in: R |
Qaphela: 1. Indlela yokufaka izintambo: ngemuva kwezintambo zepuleti (400, 630's 4P ngaphandle kwayo);i-plug-in yohlobo lwezintambo (4P ngaphandle kwayo)
2. Izesekeli zangaphakathi zifakwe ohlangothini lwesobunxele lwe-breaker.
Ithebula lokukhetha lobuchwepheshe le-GPM11Z MCCB
Uhlobo | I-voltage yokusebenza elinganiselwe i-Ue(V) | I-insulating elinganiselwe I-voltage Ui(V) | Umfutho olinganiselwe ukumelana ne-voltage Uimp (V) | Uhlaka lwesihlangu I-Inm (A) yamanje | Ikalwe okwamanje I-Inm (A) | Inombolo yesigaba | Amandla okuphuka kwesiyingi esifushane | Ilinganiselwe isikhathi esifushane ukumelana ne-Icw yamanje (kA) 1s | Ukusebenza komsebenzi | ||
Isilinganiso esiphezulu somthamo we-Icu (kA) sokuphulwa kwesekethe emfushane | Ilinganiselwe ngokusebenza komthamo we-Ics (kA) | Impilo yemishini (izikhathi) | Impilo kagesi (izikhathi) | ||||||||
I-GPM11Z-100 | I-AC400 | AC690 | AC8000 | 100 | 32, 100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
I-GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
I-GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
I-GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Ithebula lokukhetha lobuchwepheshe le-GPM11 MCCB
Uhlobo | Isilinganiso se-voltage yokusebenza i-Ue | Isilinganiso se-insulating voltage Ui | I-impulse elinganiselwe imelana ne-voltage Uimp | Isigaba sozimele silinganisele i-Inm A yamanje | Ikalwe ngo-(A) | Inombolo yesigaba | Ikalwe ngekhodi yomthamo omkhulu wokuphulwa kwesekethe emfishane | Ilinganiselwe ngobuningi obufushane -umthamo wokuphulwa kwesifunda | Ilinganiselwe ngokusebenza komthamo we-Ics (kA) | Uhlobo lwedivayisi yohambo | Ukusebenza komsebenzi (izikhathi) | |
Phila | Akukho-Live | |||||||||||
I-GPM11-63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Ukushisa kwe-electromagnetic | 3000 | 7000 |
3,4 | S | 25 | 18 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
I-GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Ukushisa kwe-electromagnetic | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic | ||||||||
I-GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Ukushisa kwe-electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic | ||||||||
GPM11-225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | Ukushisa kwe-electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic | ||||||||
I-GPM11-250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | Ukushisa kwe-electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic | ||||||||
I-GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Ukushisa kwe-electromagnetic | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic | ||||||||
GPM11-630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Ukushisa kwe-electromagnetic | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic | ||||||||
I-GPM11-800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | Ukushisa kwe-electromagnetic | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Ukushisa kwe-electromagnetic |