I-GPN1-40.5kV Removable AC Metal-clad Enclosed Switchgear
Isifinyezo
I-GPN1-40.5kV ekhiphekayo ye-AC metal-clad switchgear (ifushane ku-switchgear njengoba ingezansi) isebenza ku-40.5kV, isigaba se-3, i-AC kanye nenethiwekhi yamandla kagesi engu-50/60Hz yokwamukela nokusabalalisa amandla amandla kanye nokulawula, ukuqapha nokuvikela.Isebenza kusistimu yamandla evamile kanye nezikhathi ezisebenza njalo.Umkhiqizo uvumelana ne-GB 3906 “3~35kV AC Metal Enclosed Switchgear”, GB/T 11022 “Izigatshana zezobuchwepheshe ezivamile ze-High Voltage Switchgear kanye ne-controlgear Standard”, DL/T 404-1997 “I-Order Technical term of Indoor AC High Voltage Switchgear ” kanye ne-IEC-298 “1~52kV AC Metal Enclosed Switchgear kanye ne-Controlgear standard”.
Isimo se-Ambient
Izinga lokushisa le-ambient: -25℃~+45℃, isilinganiso sansuku zonke: ≤35℃
Ukuphakama: 1000m(Okujwayelekile);ingafika ku-4500m ukuze uthole uku-oda okukhethekile;
Umswakama ohlobene: isilinganiso sansuku zonke ≤ 95%, isilinganiso sanyanga zonke ≤ 90%;
Amandla okuzamazama komhlaba≤8 degree;
Izikhathi ezisebenzayo kufanele zingabi nezinto ezibolayo, ezivuthayo kanye nomhwamuko.
Imodeli
Isici soMkhiqizo
I-switchgear iyiyunithi yomhlangano futhi i-circuit breaker isebenzisa imodeli yaphansi yenqola yesandla.Iphethe ukushintsha nokushintshana kahle ngemuva kokuhlonyiswa nge-vacuum vacuum circuit breaker ethuthukisiwe.I-lead screw nut propulsion mechanism ifakwe kufreyimu yenqola yesandla ukuze ivimbele ekusebenzeni okunephutha kanye nokonakaliswa kwendlela yokuhambisa, inqola ingasuswa kalula;Zonke izinyathelo zokusebenza zingenziwa esimweni sokuvala;Ukukhiya okuyimpoqo phakathi kwe-main switch, inqola yesandla kanye nomnyango wephaneli ukuze uhlangabezane nezivikelo ezinhlanu;indawo ebanzi yokuxhuma izintambo eziningana ku-cubicle yekhebula.I-Earthing switch isetshenziswa kumjikelezo omfushane we-earthering kanye ne-loop, idigri yokuvikela yokubiyelwa yi-IP3X, IP2X ngaphansi kwesimo sokuvula.
Ukucaciswa Kwezobuchwepheshe
Cha. | Into | Iyunithi | Idatha | |
1 | I-voltage elinganiselwe | kV | 36/38/40.5 | |
2 | Ikalwe okwamanje | A | 1250, 1600, 2000, 2500 | |
3 | Isilinganiso sokuvama | Hz | 50/60 | |
4 | Ilinganiselwe ngokuphulwa kwesekethe emfushane | kA | 25, 31.5 | |
5 | 4s ilinganiselwe isikhathi esifushane ukumelana namanje | kA | 25, 31.5 | |
6 | Ilinganiselwe isekethe emfishane eyenza yamanje (isiqongo) | kA | 63, 80 | |
7 | Isilinganiso esiphakeme sokumelana nokumelana nokwamanje(isiqongo) | kA | 63, 80 | |
8 | Izinga le-insulation | Isilinganiso sombani simelana ne-voltage | kV | 185 (kubo bonke abathintwayo abavuliwe: 215) |
Isekhethi eyinhloko 1min imvamisa yamandla imelana ne-voltage | kV | 95 (kubo bonke abathintwayo abavuliwe: 110) | ||
Isifunda esisizayo 1min imvamisa yamandla imelana ne-voltage | kV | 2 | ||
9 | Ubukhulu bohlaka(W)*(D)*(H) | mm | 1400/2800/2600 (GPN1 uhlobo) 1200/2600/2400 (Ngohlobo lwe-VD4/HD4) | |
10 | Idigri yokuvikela | IP3X (ikhomishini IP2X) | ||
11 | Isisindo | kg | 1000-1850 (uhlobo lwe-GPN1) 850-1850 (Ngohlobo lwe-VD4/HD4) |
Isici Sesakhiwo
I-switchgear ihlukanisa ibe indawo ebiyelwe kanye nenqola yesandla, indawo ebiyelwe yenziwe nge-aluminium-zinc plated steel sheet ngemuva kokucutshungulwa umshini we-CNC nokugoba okuningi, bese ihlanganiswa namabhawodi.Ngakho-ke inamandla aqinile emishini futhi ingaqinisekisa ubunono nokubukeka okuhle.Iqukethe indawo yokudluliselana, indawo yenqola yesandla, indawo yekhebula, idigri yokuvikela i-IP2X lapho inqola yesandla ye-CB isendaweni yokuvula nokuhlola.
I-switchgear iwuhlobo olukhishwayo olugqoke insimbi, isifunda esikhulu samukela ukucubungula kokufakwa kwenhlanganisela, ukusakazeka okuphuthumayo kwezinye izingxenye.I-CT neswishi ye-earthering ifakwe ku-cable compartment kanye ne-busbar compartment.Izinga lokuvikela lokuvalekile yi-IP3X, isivikelo nesikhala esikhulu sezintambo ezimbalwa.Idizayini yesakhiwo se-VCB entsha evalekile ngokuphelele noma i-SF6 CB kanye nendlela yokusebenza yasentwasahlobo iyimodeli yekhonsoli edidiyelwe enobuhle obunjalo bokushintshana kahle nokushintsha kalula.