12/24/40.5kV Shutter Assembly And Interlocking
I-Shutter Assembly 5GP.320.010 Umdwebo Wokufaka
(800mm ububanzi obekwe maphakathi switchgear)
I-Shutter Assembly 5GP.320.010 Uhlu Lokuhlela
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
1 | Abakaki abasekelayo kwesokudla | 8GP.123.011 | 1 |
2 | Ipuleti lokuxhumana elingakwesokudla | 5GP.235.011 | 1 |
3 | Ibonisa umaka | 8GP.866.014 | 1 |
4 | Uxhumano lwesokunxele | 5GP.235.010 | 1 |
5 | Abakaki abasekela kwesokunxele | 8GP.123.010 | 1 |
6 | I-welding yokuxhumana | 5GP.174.016.1(Okwe-VD4) | 2 |
5GP.174.016.2(Okwe-GPVN) | |||
5GP.174.016.3(Okwe-VB2) | |||
7 | Isango elivala phansi | 8GP.320.010 | 1 |
8 | I-block iboshwe 8 | I-DK-8 | 8 |
9 | Ipuleti likabakaki | 8GP.123.013 | 3 |
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
10 | I-welding yokuxhumana | 5GP.174.017.1(Nge-VD4, 40kA) | 2 |
5GP.174.017.2(Nge-VD4, 31.5kA) | |||
5GP.174.017.3(Okwe-GPVN) | |||
5GP.174.017.4(Okwe-VB2) | |||
11 | Ibonisa umaka | 8GP.866.012 | 1 |
12 | Ibonisa umaka | 8GP.866.013 | 2 |
13 | Ipuleti likabakaki | 8GP.123.012 | 3 |
14 | Isivalo esiphezulu | 8GP.320.011 | 1 |
15 | Induku yomhlahlandlela | 8GP.234.011(Ye-VD4, GPVN) | 2 |
8GP.234.011.1(Ye-VB2) | |||
16 | Umkhono wokumisa | 8GP.210.011 | 2 |
Olunye uhlu lokuhlelwa kwe-shutter
Ikhodi | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Ububanzi bekhabhinethi | 650mm | 700mm | 840mm | 900mm | 1000mm |
Isango eliphezulu | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Phansi kwesango | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
I-Shutter Assembly 5GP.320.011
(I-switchgear ebekwe phakathi nendawo ububanzi engu-1000mm)
Idivayisi ye-Shutter Mechanism 5GP.320.011 Uhlu Lokuhlela
(I-switchgear ebekwe phakathi nendawo ububanzi engu-1000mm)
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
1 | Abakaki abasekelayo kwesokudla | 8GP.123.276 | 1 |
2 | Ipuleti lokuxhumana elingakwesokudla | 5GP.235.012 | 1 |
3 | Ibonisa umaka | 8GP.866.014 | 1 |
4 | Ipuleti lokuxhumana elingakwesokunxele | 5GP.235.013 | 1 |
5 | Abakaki abasekela kwesokunxele | 8GP.123.275 | 1 |
6 | Ukuhlanganiswa kwe-weld | 5GP.174.281 | 2 |
7 | Isivalo esiphansi | 8GP.320.273 | 1 |
8 | I-block iboshwe 10 | I-DK-10 | 8 |
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
9 | Ipuleti likabakaki | 8GP.123.278 | 3 |
10 | Ukuhlanganiswa kwe-welding | 5GP.174.282 | 2 |
11 | Ibonisa umaka | 8GP.866.012 | 1 |
12 | Ibonisa umaka | 8GP.866.013 | 2 |
13 | Ipuleti likabakaki | 8GP.123.277 | 3 |
14 | Isivalo esiphezulu | 8GP.320.274 | 1 |
15 | Induku yomhlahlandlela | 8GP.234.272 | 2 |
16 | Umkhono wokumisa | 8GP.210.011 | 2 |
Olunye uhlu lokuhlelwa kwe-shutter
Ikhodi | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Ububanzi bekhabhinethi | 800mm | 1000mm(I-Insulating) | 1100mm | 1200mm |
Isango eliphezulu | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Phansi kwesango | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Qaphela: I-5GP.320.275 eye-insulating shutter ngepuleti le-SMC phakathi futhi zombili ziphela ngepuleti lensimbi, enye inhlanganisela ye-shutter uma kudingeka isango lokuvikela sicela ucacise.
Idivayisi yokuvala indlela yokusebenza kwe-Earthing switch (Okokusebenza kokushayela kwengalo yokuxhumana) 5GP.363.010.1 umdwebo womhlangano
Umyalelo Wedivayisi ye-Interlock
Idivayisi yokukhiya yengezwa i-interlock engemuva enomnyango ongemuva eklanywe ngesisekelo sedivayisi yokuqala engu-5GP.363.010 yokushintsha indlela yokusebenza yokushintsha indlela yokushintshanisa.Okusho ukuthi, ngemva kokuba iswishi ye- earthing ivaliwe futhi kwavula umnyango ongemuva (ipuleti lokufaka uphawu), isikhiye soqobo sasisakwazi ukusebenzisa iswishi ye- earthing, kodwa lokhu kukhiya akukwazanga.Kumelwe uqale uvale isicabha sangemuva (ipuleti lokuvala) ukuze usebenzise iswishi yokufaka umhlaba.
Izimiso zokusebenza zedivayisi yokukhiya zishintshwa umkhono wokukhiya onguNombolo 24 ube yilokho okubonisa kwesokudla nentwasahlobo eyengezwe ngesisekelo se-5GP yasekuqaleni .363.010.Uma umnyango ongemuva (ipuleti lokuvala) uvuleka, umkhono wokukhiya ungena embotsheni eyisikwele yekhabhinethi (usayizi otuswayo ongu-35X35), iswishi ye- earthing ayikwazi ukusebenza.
Idivayisi yokuvala indlela yokusebenza kwe-Earthing switch (Ngohlelo lokusebenza lokushayela ingalo yokuxhuma)
5GP.363.010.1 uhlu lokuhlelwa.
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
1 | Ukuzala | 8GP.263.011 | 1 |
2 | Umkhakha | 8GP.192.010 | 1 |
3 | Umkhakha | 8GP.192.011 | 1 |
4 | Umkhono we-eksisi | 8GP.210.014.1 | 2 |
5 | Umkhakha | 8GP.151.041 | 1 |
6 | Umkhono we-eksisi | 8GP.211.061 | 1 |
7 | Umkhakha | 8GP.151.039 | 1 |
8 | Umkhono we-eksisi | 8GP.211.062 | 1 |
9 | I-Bolt M5×12 | GB70-85 | 1 |
10 | Umkhakha | 8GP.151.042 | 1 |
11 | Umkhakha | 8GP.151.043 | 1 |
12 | Induku yokusebenza | 8GP.200.013.1 (Inde engu-1432 yokujula kwekhabhinethi okungu-1500) | 1 |
8GP.200.013.2 (Inde engu-1590 yokujula kwekhabhinethi 1660) | 1 | ||
13 | Ipuleti elisekelayo | 8GP.161.058 | 1 |
8GP.161.058.1(Ngokhetho) | 1 |
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
14 | Ikhava | 8GP.017.011.1 | 1 |
15 | Ubakaki | 5GP.043.022 | 1 |
16 | Ipuleti elisekelayo | 8GP.161.059 | 1 |
17 | Isilayidi | 8GP.143.010 | 2 |
18 | Umkhono we-eksisi | 8GP.211.058 | 1 |
19 | Umkhono wokumisa | 8GP.211.057 | 3 |
20 | Isisekelo sokusekela | 8GP.043.019 | 1 |
21 | Vala okukhombisayo | 8GP.866.010 | 1 |
22 | Ukuhlanganiswa kwenduku yokuxhuma | 5GP.233.030.1 | 1 |
5GP.233.030.3(Ngokhetho) | 1 | ||
23 | Vula inkomba | 8GP.866.011 | 1 |
24 | Umkhono wokukhiya | 8GP.211.201 | 1 |
25 | Ipuleti lepulaki yezinyo | 8GP.151.044 | 1 |
26 | Umkhono we-eksisi | 8GP.211.060 | 2 |
27 | Maka | 8GP.860.010 | 1 |
28 | Intwasahlobo yokucindezela | 8GP.282.201 | 1 |
29 | I-Bolt yokulungisa imikhono yokukhiya | 8GP.920.002 | 1 |
Qaphela:
1. No. 1~12 bona ikhasi eledlule.
2. No. 22 Ukuhlanganiswa kwenduku yokuxhuma, ingalo yokuxhuma inosayizi ababili: Ibanga lesikhungo seKhabhinethi elingu-60mm ngokufanayo.Uma udinga isikhungo sebanga elingu-80mm sicela uhlole ikhasi 17 umyalelo wokuhlanganisa ingalo, futhi ucacise lapho u-oda.
Idivayisi yokuvala indlela yokusebenza yokushintsha umhlaba (Ngomsebenzi we-bevel gear drive) 5GP.577.1001
Idivayisi yokuvala indlela yokusebenza yokushintsha umhlaba (Ngomsebenzi we-bevel gear drive) 5GP.577.1001 uhlu lokuhlelwa
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
1 | Ukuzala | 8GP.263.011 | 1 |
2 | Ipuleti lokumisa | 8GP.151.084 | 2 |
3 | Umkhono we-eksisi | 8GP.210.014.1 | 2 |
4 | Umkhakha | 8GP.151.041 | 1 |
5 | Umkhono we-eksisi | 8GP.210.014.2 | 1 |
6 | I-Bolt M 5X12 | GB70-85 | 1 |
7 | Umkhakha | 8GP.151.042 | 1 |
8 | Umkhakha | 8GP.151.043 | 1 |
9 | Umkhono we-eksisi | 8GP.210.014.3 | 1 |
Cha. | Igama | Inombolo yomdwebo. | Qty.(i-pc/set) |
10 | Umkhono wokumisa | 8GP.210.322 | 1 |
11 | Induku yokusebenza | 8GP.174.214 | 1 |
12 | Ikhava | 8GP.017.011.2 | 1 |
13 | Isisekelo sokusekela | 5GP.043.022 | 1 |
14 | Isilayidi | 8GP.143.010 | 2 |
15 | Ipuleti elisekelayo | 8GP.161.059 | 1 |
16 | Ipuleti elisekelayo | 8GP.161.058 | 1 |
17 | Ipuleti lepulaki yezinyo | 8GP.151.044 | 1 |
18 | Maka | 8GP.860.010 | 1 |
Qaphela: 1. Le mishini idinga ukukhiywa nomnyango ophansi, sicela ucacise lapho u-oda.