Izinkomba kanye Nemitha Yamandla
Uhlobo Incazelo
Uhlobo | Into | Indlela yokubonisa | Amandla | Ukukhiya eyodwa | Ukukhiya othintana naye ababili | Faka | Uqobo lwakho | Ubukhulu | Ukusika usayizi | Umfanekiso | |
hlola | othintana naye | hlola | |||||||||
Uhlobo lwe-builtin | I-GPXN-Q | Cindezela ukhiye | - | 96×48×88 | 91x44 | 3 | |||||
I-GPXN-T | Cindezela ukhiye | 96×48×55 | 91x44 | 3 | |||||||
Swg. | I-GPXN1-Q | Ukukhanya | - | - | 96×48×88 | 91x44 | 1 | ||||
I-GPXN1-T | Ukukhanya | - | 96×48×55 | 91x44 | 1 | ||||||
I-GPXN4-Q | Cindezela ukhiye | - | - | 144×48×104 | 138×44 | 4 | |||||
I-GPXN4-T | Cindezela ukhiye | - | 144×48×104 | 138×44 | 4 | ||||||
I-GPXN5-Q | Cindezela ukhiye | - | - | 96×48×88 | 91x44 | 2 | |||||
I-GPXN5-T | Cindezela ukhiye | - | 96×48×55 | 91x44 | 2 | ||||||
I-Insulator eyodwa enezinkomba ezi-2 | I-GPXN4-Q/M | Cindezela ukhiye | - | - | 144×48×104 | 138×44 | 4 | ||||
I-GPXN4-T/M | Cindezela ukhiye | - | 144×48×104 | 138×44 | 4 | ||||||
I-GPXN4-T/Z | Cindezela ukhiye | 144×48×104 | 138×44 | 4 | |||||||
Uhlobo Olukhethekile | I-GPXN1-Q/CS | Ukukhanya | - | - | - | 96×48×88 | 91x44 | ||||
I-GPXNP1-Q/W | Ukukhanya | - | - | - | 96×48×88 | 91x44 | 1 | ||||
I-GPXN-Q/LCS | Ukukhanya | - | - | 96×48×88 | 91x44 | 3 |
Inkomba Yamandla Kagesi Esetshenziswa Kuyunithi Eyinhloko Yendandatho
Inkomba ye-voltage isetshenziswa kanye ne-insulator ukukhombisa isimo se-electriferous of the voltage circuitry.
I-continuous voltage detector GPXN9-C isetshenziswa ne-indicator ukukhombisa isimo sikagesi.Ibanga lembobo letheminali yokuhlola amandla ngu-14mm noma 19mm.
I-Phase comparator i-GPXN-C isetshenziswa ne-indicator ukukhombisa isimo sikagesi sokujikeleza kwe-voltage ephezulu kanye nokuhlola ukulandelana kwesigaba semishini kagesi.
Ukuhlola amandla: isifanisi sesigaba faka endaweni yokubeka phansi noma kwamanye amatheminali emishini yamandla kagesi aphezulu.
Ukuhlolwa kwesigaba: faka isiqhathanisi sesigaba endaweni efanayo yokuhlola amandla emishini emibili yamandla kagesi aphezulu, uma isibani se-LED sigqamile, sibonisa ukuthi isigaba sokuhlola sinokunikezwa kwamandla.
Inkomba Yesikhundla
Isikhombi sesikhundla singalingisa indawo yokusebenza nesimo semishini yokushintsha njengeswishi nesiphazamisi sesekethe kusistimu kagesi.Isetshenziswa kakhulu kuzo zonke izinhlobo zebhodi lokulingisa legumbi eliphakathi lokulawula kanye nephaneli ye-switchgear embonini yamandla, esiteshini samandla kanye nasesiteshini se-transformer.Lolu chungechunge lwezinkomba zesikhundla lunokwethenjelwa okuphezulu, ububanzi obubanzi bamandla okusebenza kanye nempilo ende.I-DC ne-AC iyatholakala ukuze isetshenziswe.
Imingcele Yezobuchwepheshe
I-voltage elinganiselwe | I-DC/AC 98V~242V |
Amandla akhanyayo | >40 cd/㎡ |
Imvamisa yamandla imelana ne-voltage | 2kV/1min |
Ukumelana ne-insulation | ≥100MΩ |
Ukuchithwa kwamandla | ≤1W |
Izinga lokushisa lokusebenza | -15 ℃ ukuze +50 ℃ |
Ubude bempilo | Iminyaka engu-10 |
Umsebenzi wokubonisa | Isimo sokusebenza sikhonjiswe ngombala obomvu/oluhlaza kanye nezithombe (Njengenketho yamakhasimende) |
Ubukhulu bohlaka: | 37.5×37.5×62(mm) |
Usayizi wokusika: | Φ25(mm) |
Imodeli | Incazelo |
I-GPWZ25-K/2 | Isikhundla Indicator-Circuit-Breaker |
I-GPWZ25-E/1 | I-Position Indicator-Earthing Switch |
I-GPWZ25-B/2 | Iloli Lokuphatha Inkomba Yesikhundla |
I-GPWZ25-B/1 | Isikhundla Inkomba-Isixhumi |
I-GPWZ25-K/1 | Inkomba yesikhundla-Shintsha izikhundla Ezintathu |
Isikhundla Esibonisa Isikrini se-GPAS-72
Indawo ye-serial ye-GPAS-72 ebonisa isikrini samukela i-LED njengomthombo wokukhanya, esebenzisa amandla aphansi, ukwethembeka okuphezulu, impilo ende yesevisi, njll. Futhi ingasetshenziswa kuzo zonke izinhlobo zama-switchgear njengendawo ebonisa isikrini esinezixazululo ezihlukene zemidwebo yesistimu.Ngemisebenzi eminingi kangaka yenkomba yesigaba-voltage, ukukhiya, ukulawula izinga lokushisa nokuswakama, inkomba yendawo yenqola ephathwayo, inkomba yesimo se-circuit breaker, inkomba yesimo sokushintsha komhlaba, inkomba yamandla agciniwe.Kuyisinqumo esihle sokushintsha inkomba yesimo sesimo sokushintsha okukodwa.
Imingcele Yezobuchwepheshe
I-voltage elinganiselwe | I-AC/DC 110V/220V |
Ukumelana nefrikhwensi yamandla | 2kV/min |
Indawo yokusebenza | -25℃ kuya ku-55 ℃, ≤90%RH |
Ukukhanya kokukhanya kwenkomba ye-analog | >40cd/m2 |
Impilo yokusebenza | Iminyaka engu-10 |
Izinga lokuvikela | IP42 |
Ubukhulu | 199x146x63mm |
Ukusika usayizi | 177x121mm |
I-Technical ParametersGpj-3100 Uchungechunge Lwesekethe Emfishane Nesikhombi Sephutha Lomhlaba
Uchungechunge lwe-GPJ-3100 lwesekhethi emfishane kanye nesikhombi sephutha lomhlaba siklanyelwe ukuhlola futhi sibonise isifunda esifushane kanye nephutha lomhlaba ngesikhathi sangempela.Isetshenziselwa ukuqapha ukujikeleza ku-RMU, umugqa ongaphezulu, umugqa wokusabalalisa ikhebula lamandla, i-box-type transformer nezinye izindawo ezifanayo.Ngokwesiginali ye-alamu ekhonjiswa yinkomba, abasebenzi bangakwazi ukuthola futhi banqamule indawo yephutha ngokushesha lapho isifunda esifushane noma iphutha lomhlaba lenzeka kumjikelezo, ukuze uhlelo lukwazi ukuthola amandla okunikeza indawo engenaphutha ngokushesha ukuze konge isikhathi futhi kuthuthukiswe ukusebenza kahle.
Idatha Yezobuchwepheshe
1. Isifunda esifushane samanje esithusayo: 100A kuya ku-1000A ukubambezeleka kwesikhathi 40ms
2. I-Earthering current ethusayo: 20A,30A,40A,50A,60A±10% ukubambezeleka kwesikhathi 40ms
3. Ibanga lokushisa : -25 ukuya +70 ℃
4. Ibanga lomswakamo: ≦95%
5. Ubude bomthofu womhlaba: 4m
6. Yenza ubude be-fiber optical 3.5m
7. Ukunikezwa kwamandla: ibhethri ye-lithium 3.6V/2.45Ah
8. Isikhathi sokusetha kabusha ngokuzenzakalela: 7s, 2hrs,4hrs,8hrs
9. Ukudluliselwa komphumela : 120 V AC 1A, 30V DC 2A
10.Ubukhulu besilawuli esikhulu : 95x50x80mm
11.Usayizi wembobo yokusika : 91x44 mm
12.Isigaba sokuvikela : Isilawuli Esiyinhloko :IP40, Inzwa:IP65