40.5kV Outdoor Vacuum Circuit Breaker
Uhlolojikelele Lomkhiqizo Nokusetshenziswa
I-ZW7A-40.5: I-CT yakhelwe ngaphakathi noma ngaphandle, futhi ukwahlukanisa kwangaphandle ukubukeka komzimba kwerabha ye-silicone noma i-porcelain.
Imodeli Yomkhiqizo Nencazelo
Izimo zokusebenza
Izimo zokusetshenziswa ezijwayelekile
a.Ukushisa komoya okuzungezile, ubuncane -30 °, ubuningi +40 °;izinga lokushisa elilinganiselwe elikalwe phakathi kwamahora angu-24 alidluli ku-35 °;
b.Ukuphakama akudluli ku-1000m;
c.Izinga lokungcola komoya ozungezile akufanele lidlule izinga II;
d.Umoya ozungezile ngokusobala awungcoliswa uthuli, intuthu, igesi ebolayo noma evuthayo, isitimu noma isifutho sikasawoti;
e.Ubukhulu be-icing akufanele budlule i-20mm;
f.Isivinini somoya asidluli ku-34m/s;
g.I-fissure yokuzamazama komhlaba ayidluli ama-degree angu-8;
h.Izimo zokuswakama:
Isilinganiso senani lomswakamo olinganiselwe okalwe phakathi kwamahora angama-24, ongadluli ku-95%;
Isilinganiso senani lokucindezela komhwamuko okalwa phakathi kwama-24h aweqi ku-2.2kPa;
Umswakama ojwayelekile wanyanga zonke aweqi ama-90%;
Isilinganiso sanyanga zonke sokucindezela komhwamuko wamanzi aweqi ku-1.8kPa;
Uma izimo zokusetshenziswa ezijwayelekile ezibalwe ngenhla zeqiwa, sicela uthintane nomkhiqizi kusengaphambili, futhi sicela ucacise lapho u-oda;
Izimo zokusebenzisa okungajwayelekile
Kubandakanya indawo yokusetshenziswa ngokweqile efana nokuphakama okungaphezu kwamamitha ayi-1000, ukushintsha kwezinga lokushisa okusheshayo, uqweqwe olungaphezulu kuka-20mm, ukungcola okukhulu, ukujiya okukhulu, isikhutha, isihlabathi, uthuli, amakhaza amakhulu, ukushisa okushisayo, ukudlidliza, umthelela, ukushwibeka, njll., sicela uxoxisane kusengaphambili uma uyala.
Imingcele Eyinhloko Yezobuchwepheshe Yemikhiqizo Yochungechunge lwe-Zw7
Cha. | Incazelo | Iyunithi | Idatha | ||
1 | I-voltage elinganiselwe | kV | 40.5 | ||
2 | 1 imiz Isilinganiso samandla esilinganiselwe ukumelana ne-voltage 1min | kV | 95 | ||
3 | Isilinganiso sombani simelana ne-voltage | kV | 185 | ||
4 | Isilinganiso sokuvama | Hz | 50 | ||
5 | Ikalwe okwamanje | A | 630, 1250, 1600, 2000, 2500 | ||
6 | Ilinganiselwe isikhathi esifushane ukumelana nokwamanje | kA | 20 | 25 | 31.5 |
7 | Isilinganiso esiphakeme sokumelana namanje | 50 | 63 | 80 | |
8 | Ilinganiswe ngokuphuka kwesiyingi esifushane | 20 | 25 | 31.5 | |
9 | Ilinganiselwe ukwenza i-short-circuit yamanje | 50 | 63 | 80 | |
10 | Ilinganiselwe ubude besikhathi esifushane | s | 4 | ||
11 | Ingxenye ye-DC yesilinganiso sokunqamuka kwesiphambano esifushane |
| 51 | ||
12 | Inani eliphakeme kakhulu le-transient recovery voltage (TRV) | kV | 114 | ||
13 | Isilinganiso sokuphakelwa kwamandla kagesi wamadivayisi wokuvala nokuvula namasekhethi asizayo | V | I-DC/AC 220V, DC/AC 110V | ||
14 | Ilinganiswe ngokulandelana kokusebenza |
| O-0.3s-CO-15s-CO | ||
15 | Isikhathi sokuvula | ms | 20 - 50 | ||
16 | Isikhathi sokuvala | 30 - 80 | |||
17 | Isilinganiso sesikhathi se-DC sesilinganiso sokunqamuka kwesiphambano esifushane | 45 | |||
18 | Isilinganiso sokushaja kwekhebula okwamanje | A | 50 | ||
19 | Impilo yesevisi |
| I-E2-C2-M2 (10000) | ||
20 | Ilinganiselwe izikhathi zokuphuka kwesiyingi esifushane | Izikhathi | 20 |
Ithebula Lepharamitha Yokulungiswa Komhlangano Wemikhiqizo Yochungechunge lwe-Zw7
Cha. | Incazelo | Iyunithi | Idatha |
1 | Ibanga lokuvula lokuxhumana | mm | 20±2 |
2 | I-stroke yokuxhumana | 4±1 | |
3 | Isivinini esimaphakathi sokuvala (othintana naye wokulinganisa ngaphambi nje kokuvala ku-10mm ngaphambi kokuvala) | m/s | 0.8±0.3 |
4 | Isivinini esimaphakathi sokuvula (othintwayo wokulinganisa usanda kuhlukaniswa waba ngu-10mm ngokuhlukana) | 1.6±0.3 | |
5 | Isikhathi sokugxuma sokuxhumana sivala | ms | ≤5 |
6 | Isikhathi sokugxuma sokuxhumana sivala | ≤2 | |
7 | Ukuvulwa kokuxhumana okunezigxobo ezintathu ngezikhathi ezahlukene | ≤2 | |
8 | Ukumelana kwesekethe okuyinhloko kwesigxobo ngasinye | μΩ | ≤100(Ngaphandle kwesiguquli sensimbi) |
9 | Qaphela: Imingcele engenhla ibhekisela ku-voltage elinganiselwe yokusebenza |
Ubukhulu bokufaka
Ekuphakameni okungamamitha ayi-1000 (ibanga eliphakathi nendawo lika-710mm), ukuphakama okungamamitha ayi-2000 (ibanga elimaphakathi lama-780), kanye nokuphakama okungamamitha angu-3000 (ibanga elimaphakathi lama-850), ubukhulu bubonke ama-circuit breaker ami kanje:
Ekuphakameni kwamamitha angu-4000 (ibanga eliphakathi nendawo 920), kumamitha angu-5000 (ibanga eliphakathi nendawo 1000) amamitha, izilinganiso eziphelele ze i-circuit breaker imi kanje: