I-MNS I-Voltage Ephansi Ehoxiswayo ye-MCC Switchgear
I-GPM1 I-Low-voltage Withdrawable Switchgear
I-GPM1 low-voltage withdrawable switchgear ubuchwepheshe be-ABB obuthuthukisiwe be-low-voltage switchgear.
I-GPM1 iyikhabethe le-modular, elinemisebenzi eminingi eliphansi lokusatshalaliswa kwamandla kagesi emhlabeni eminyakeni engaphezu kwengama-40 yomlando wokusebenza, lisetshenziswa kabanzi kwezensimbi, kuphethiloli, kumabhizinisi amakhemikhali, ezimbonini nasezimayini, nengqalasizinda yazo zonke izikhathi ezidinga ukuthembeka okuphezulu kwamasistimu kagesi aphansi. , ukusatshalaliswa kwamandla kanye nezinhlelo zokulawula izimoto.
Le divayisi iyifekthri yemojula evamile ehlanganiswe i-modular low-voltage switchgear ye-AC 50-60Hz, i-voltage yokusebenza elinganiselwe engu-600V nangaphansi kwesistimu yamandla okukhiqiza amandla, ukudlulisa, ukusatshalaliswa, ukuguqulwa kwamandla kanye nokulawula ukusetshenziswa kwamandla kwemishini esetshenzisiwe.
Ikhabethe le-GPM1 livumelana nezimo kakhulu, lingafakwa kumamodeli ahlukahlukene kanye nokucaciswa kwezingxenye ngokuya ngezidingo ezithile kanye nezikhathi ezahlukahlukene.Kungenjalo, ungancika ezinhlotsheni ezahlukene zeyunithi yokuphakela impahla kagesi efakwe kukholomu efanayo noma ikhabethe elifanayo namasekhethi okuphakelayo namasekhethi okulawula izinjini kungaxutshwa ndawonye.
I-GPM1 low-voltage withdrawable switchgear iwuhlu olugcwele lwe-low-voltage switchgear, isistimu ye-low-voltage ifanele wonke ama-5000A amanje akalwe noma ngaphansi.
Imidwebo: 8E/4, 8E/2, 8E, 12E, 16E, 20E, 24E yohlelo lwekhabhinethi nezinketho ezihlukahlukene.
Umhlangano Osebenzayo Wesigaba
Isiteshi sepulasitiki se-busbar esinemisebenzi eminingi sihlanganiswa phakathi kwegumbi lesekethe elikhulu negumbi likagesi.
Kwenziwe ngezinto zobunjiniyela ezishisayo nezimile.Inezici ze-anti-fire, ezinamandla, eziphakeme kakhulu kanye ne-anti-impulse ephezulu kanye nemisebenzi yokugwema ngokuphumelelayo izingozi zokushintsha okubangelwa umjikelezo omfushane phakathi kwe-arc kanye nesifunda esikhulu esiphakanyiswe ukungasebenzi kahle.
I-voltage yayo elinganiselwe ingu-380V (660V), futhi isilinganiso sikagesi esiphezulu singu-176KA, kanti isikhathi esifushane sikagesi samanje singu-50kA~80kA (1s).Ipuleti lesiteshi sebhasi elinemisebenzi eminingi (5GP 742 001) lihlanganiswe neziphetho ezimaphakathi eziyi-9, iziphetho zesiteshi ezi-2, umugqa werabha we-gasket kanye nephedi.Ingabona futhi ukufakwa okuxubile kweKhabhinethi ye-PC kanye nekhabhinethi ye-MCC.Uma kushintsha indawo yesiphetho sesiteshi ngepuleti elihlukanisayo, izosetshenziswa ngobubanzi obungu-600 be-MCC obungemuva obukhiphayo bokushintshashintsha.
Le mikhiqizo eyenziwe ngezinto eziqine kakhulu futhi esetshenziswa kakhulu ekulungiseni u-50mm×30mm×5mm L uhlobo lwesekethe eyinhloko eqondile.